Download Print this page

Siemens SIMATIC RF600 Series System Manual page 55

Simatic ident
Hide thumbs Also See for SIMATIC RF600 Series:

Advertisement

Cable vendors usually provide tables or calculation aids for their types of cable which usually
include the transmitter and receiver frequencies as well as the cable length. Therefore
contact your cable vendor in order to determine the appropriate type of cable using the
approximate value referred to above.
Notes on use
Shielding of the antenna cable
Coaxial antenna cables always have a shielded design and therefore radiate little of the
transmitted power to the environment.
Note
Cable with double shielding
You should therefore preferentially select cable with double shielding since this provides the
best damping.
Bending radius of the antenna cable
The properties of the cable shield are influenced by mechanical loading or bending. You
must therefore observe the static and dynamic bending radii specified by the cable vendor.
Connectors and adapters
You must use connectors and adapters of type "Reverse Polarity R-TNC" (male connector)
for your antenna cables from a third-party supplier in order to ensure correct connection to
the RF600 reader interface.
The figure below shows the standard for a suitable thread:
You can find more information in the catalog data of your cable vendor.
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
RF600 system planning
4.3 Antenna configurations