Transponder
7.1 Overview
SIMATIC RF685R
with internal antenna
with RF620A
with RF640A
with RF642A
with RF650A
with RF660A
with RF680A
Mounting on a non-metallic surface. Mounting surface with a minimum diameter of 300 mm. Mounting on metal is not
1)
possible.
Mounting on metal Mounting surface with a minimum diameter of 150 mm.
2)
With the transponder RF622T the write/read ranges are identical. However the write/read range of this transponder
3)
sinks constantly as of an amount of data ≥ 100 bytes.
Table 7- 6
Read range of the transponders IV (all ranges in meters [m])
SIMATIC RF650R
with RF620A
with RF640A
with RF642A
with RF650A
with RF660A
with RF680A
SIMATIC RF680R
with RF620A
with RF640A
with RF642A
with RF650A
with RF660A
with RF680A
SIMATIC RF685R
with internal antenna
with RF620A
with RF640A
with RF642A
with RF650A
with RF660A
with RF680A
Mounting on metal Mounting surface with a minimum diameter of 150 mm, for the RF630T and RF680T 300 mm.
1)
300
SIMATIC RF620T
1)
7.0
0.85
6.0
8.0
8.0
8.0
8.0
SIMATIC RF630T
1)
0.3
1.5
2.0
1.5
2.0
1.3
0.4
2.0
2.0
2.0
2.0
2.0
2.0
0.4
2.0
2.0
2.0
2.0
2.0
SIMATIC RF622T
2) 3)
3.0
0.4
2.5
3.0
3.1
3.0
4.3
SIMATIC RF640T
1)
0.6
3.0
4.0
3.0
4.0
2.7
0.9
4.0
4.0
4.2
4.0
4.3
4.0
0.9
4.0
4.0
4.2
4.0
4.3
System Manual, 10/2016, J31069-D0171-U001-A19-7618
SIMATIC RF625T
2)
1.5
0.5
1.2
1.5
1.3
1.5
2.0
SIMATIC RF680T
1)
0.6
3.0
4.0
3.0
4.0
2.7
0.9
4.0
4.0
5.0
4.0
5.0
4.0
0.9
4.0
4.0
5.0
4.0
5.0