Digital and analog NCK I/Os (A4)
1.3 NCK I/O via PROFIBUS
CC-Bindings
The following CC-bindings are available:
CCDataOpi: getDpIoRangeConfiguration()
CCDataOpi: getDpIoRangeValid()
CCDataOpi: getDpIoRangeInInformation()
CCDataOpi: getDpIoRangeOutInformation()
CCDataOpi: getDpIoRangeInState()
CCDataOpi: getDpIoRangeOutState()
CCDataOpi: getDataFromDpIoRangeIn()
CCDataOpi: putDataToDpIoRangeOut()
Note
● The bindings
● If an attempt is made to access an I/O-range which is not configured (or not configured
60
CCDataOpi: getDataFromDpIoRangeIn() or
CCDataOpi: putDataToDpIoRangeOut()
monitor during the read/write accesses the adherence to the limits of the respective
I/O-range configured at the NCK and PLC-side. Access to data/data ranges, which do
not lie completely within the configured I/O-range limits, are rejected by returning the
enumerator CCDATASTATUS_RANGE_LENGTH_LIMIT.
for the compile cycle), it is notified by means of the return-enumerator
CCDATASTATUS_RANGE_NOT_AVAILABLE.
NOTICE
The compile cycle programmer himself is responsible for the correct use of the
CC-bindings! It must be noted that the additional performance requirement needed for
providing the data of the configured I/O-ranges at the Servo-task level, does not lead
to a Servo-level computing time overflow.
See the OEM documents for more information about the use of these bindings.