Addendum - GE eBike III basic Series Service Manual

Electric bike with and without nibp
Table of Contents

Advertisement

a
ddenduM
e
s
rrorCodes
oftware e
Every electronic module of the eBike III ergometers has its own error codes.
If an error occurs, a hexadecimal code is displayed on the ergometer display and internally stored with date/time of first
occurence and numbers of recurrences.
The displayed hexadecimal code is a combination of single error bits, each representing a special fault condition.
example: Displayed Error
Bit conversion:
Error bits set:
A service software to download Error codes and device settings from the eBike III
is available (downloadable) from Infocenter / section software download / eBike
III service tool
e
dtu (C
rror Code BIts
ontrol terMInal
Bit
Error
0
Illegal program jump
1
Wrong SW configuration
2
not used
3
LCD communication error
4
+24V out of range
5
not used
6
not used
7
Safety state mode
8
not used
- 94 -
B
III
Ike
Source:
DTU
Err.Code:
0018 (hexadecimal)
0 0 0 0
Bit 3
LCD communication error
Bit 4
+24V out of range
Note
pCB)
Reaction
Safety shut down
Safety shut down
Safety shut down
eBike III basic / comfort
0 0 0 0
0 0 0 1
Display / Info
Troubleshooting
- restart eBike (OFF / ON)
- if error persists:
Warning
- perform software update
- check LCD connection
- if error persists:
Internal error
- check power supply
- check connections:
- restart eBike (OFF / ON)
- if error persists:
1 0 0 0
(0018 hex)
replace control terminal
replace control terminal
power supply to switch to LIU
cable DTU <-> LIU
replace control terminal