Serial Port Interface; Figure 2-13. Type 3 Atcs Address Screen - Siemens A53457 Installation & Maintenance

Wayside access gateway wag
Table of Contents

Advertisement

2. Do the following:
a. To keep all of the current displayed values, press ENTER.
b. To enter a new value, type the first 3 digits of the new Type 3 ATCS address (RRR) and
press ENTER.
c. To enter a new value, type the second 2 digits of the new Type 3 ATCS address (SS) and
press ENTER.
d. To enter a new value, type the third 4 digits of the new Type 3 ATCS address (DDDD) and
press ENTER.
When finished, the user will be returned to the First Configuration Menu. The new Type 3
ATCS address is displayed.
3. Prior to exiting the First Configuration Menu, select "Save changes then restart" to save
changes and restart the WAG.
2.6.3

Serial Port Interface

The user can make changes to the serial interface baud rate configure the number of data and
stop bits on the serial interface, enable or disable the flow control, and the ability to insert parity
bits. If the user changes the baud rate from the default of 9600, the baud rate for the computer
the WAG is connected to will also need to be changed.
To Change the Serial Port:
1. On the First Configuration Menu, select serial port to be changed. The Serial Port selection
screen appears.
Document No.: COM-00-05-16
Version: C.1

Figure 2-13. Type 3 ATCS Address Screen

2-13
INSTALLATION AND CONFIGURATION
June 2006, Revised June 2014