Configuring Ip Interworking Over An Ldp Pw - HP MSR2000 Configuration Manual

Msr series mpls
Hide thumbs Also See for MSR2000:
Table of Contents

Advertisement

# Verify that CE 1 and CE 2 can ping each other. (Details not shown.)

Configuring IP interworking over an LDP PW

Network requirements
CE 1 and PE 1 are connected through Ethernet interfaces. CE 2 and PE 2 are connected through serial
interfaces, and they use PPP as the link layer protocol.
Configure an LDP PW between PE 1 and PE 2 and enable interworking on PEs so GigabitEthernet 2/1/1
on CE 1 can communicate with Serial 2/1/0 on CE 2.
Figure 101 Network diagram
Table 37 Interface and IP address assignment
Device
CE 1
PE 1
CE 2
Configuration procedure
1.
Configure CE 1.
<CE1> system-view
[CE1] interface gigabitethernet 2/1/1
[CE1-GigabitEthernet2/1/1] ip address 100.1.1.1 24
[CE1-GigabitEthernet2/1/1] quit
2.
Configure PE 1:
# Configure an LSR ID.
<PE1> system-view
[PE1] interface loopback 0
[PE1-LoopBack0] ip address 192.2.2.2 32
[PE1-LoopBack0] quit
Interface
IP address
GE2/1/1
100.1.1.1/24
Loop0
192.2.2.2/32
GE2/1/1
-
GE2/1/2
10.1.1.1/24
S2/1/0
100.1.1.2/24
Device
Interface
P
Loop0
GE2/1/1
GE2/1/2
PE 2
Loop0
S2/1/0
GE2/1/1
401
IP address
192.4.4.4/32
10.1.1.2/24
10.2.2.2/24
192.3.3.3/32
-
10.2.2.1/24