Event
Event
Code
Class
01
Major
04
Major
08
Major
12
Major
17
Minor
18
Minor
26
Minor
31
Minor
Internal Spectrum Analyzer
The radio contains a built-in spectrum analyzer tool that can be dis-
played on a connected PC. This utility is helpful in diagnosing inter-
ference problems, or for use during initial setup of the radio.
05-4669A01, Rev. A
Table 4. Event Codes
Description
Improper software detected for this radio model.
One or both of the internal programmable
synthesizer loops is reporting an out-of-lock
condition.
The system is reporting that it has not been
calibrated. Factory calibration is required for proper
radio operation.
Receiver time-out. No data received within the
specified receiver time-out time.
A data parity fault has been detected on the COM2
INTERFACE connector. This usually indicates a
parity setting mismatch between the radio and the
RTU.
A data framing error has been detected on the
COM2 INTERFACE connector. This may indicate a
baud rate mismatch between the radio and the RTU.
The DC input voltage is out-of-tolerance. If the
voltage is too far out of tolerance, operation may fail.
The transceiver's internal temperature is
approaching an out-of-tolerance condition. If the
temperature drifts outside of the recommended
operating range, system operation may fail.