Appendix 1 Comparison, Differences and Compatibility between New and Conventional
Models
(1) Comparison between AJ65VBTCU-68ADV/ADI and AJ65VBTCU-
Comparison between AJ65VBTCU-68ADV/ADI and AJ65VBTCU-68ADVN/ADIN
Item
AJ65VBTCU-68ADV/ADI
Ver. 1 remote device station (ver. 1 compatible slave
System
station) or remote device station
compatibility
(Station type,
mode)
Remote net ver. 1 mode or remote net mode
Number of
3 stations (RX/RY 32 points each, RWr/RWw 12 points
occupied
each)
stations
On
: During normal operation
Flicker : 0.1s intervals Input range setting
Operation
status
Normal
indicator
0.5s intervals Average value setting
mode
LED/RUN
LED
Off
: 24VDC power off or watchdog timer
error
AJ65VBTCU-68ADV
0: Normal mode
1: Test mode (user range setting 1)
2: Test mode (user range setting 2)
3 to 7: Reserved
Mode select
switch
(factory
AJ65VBTCU-68ADI
setting "0")
0: Normal mode
1: Test mode (user range setting)
2 to 7: Reserved
App - 1
68ADVN/ADIN
The following table indicates the comparison between the AJ65VBTCU-
68ADV/ADI and AJ65VBTCU-68ADVN/ADIN.
error, mode select
switch setting error
(number of times,
time) error
AJ65VBTCU-68ADVN/ADIN
• Ver. 1 remote device station (ver. 1 compatible slave station) or
remote device station
• Ver. 2 remote device station (ver. 2 compatible slave station)
• Remote net ver. 1 mode or remote net mode
• Remote net ver. 2 mode
• Remote net additional mode
Ver. 1 remote device station (ver. 1 compatible slave station)
setting: 3 stations (RX/RY 32 points each, RWr/RWw 12 points
each)
Ver. 2 remote device station (ver. 2 compatible slave station)
setting: 1 station (RX/RY 32 points each, RWr/RWw 16 points each)
On
: During normal operation
Flicker : 0.1s intervals Input range setting error, mode
select switch setting error, or when
this module is set as the ver. 2
remote device station (ver. 2
compatible slave station) and used
Normal
with the remote net ver. 1 mode
mode
selected in the mode setting of the
network parameter.
0.5s intervals Average value setting (number of
times, time) error, or when the
mode select switch setting is
changed after power-on.
Off
: 24VDC power off or watchdog timer error
AJ65VBTCU-68ADVN
Ver. 1 remote device station
0: Normal mode
(Ver. 1 compatible slave
1: Test mode (user range setting 1)
station)
2: Test mode (user range setting 2)
Ver. 2 remote device station
3: Normal mode
(Ver. 2 compatible slave
4: Test mode (user range setting 1)
station)
5: Test mode (user range setting 2)
6 to 7: Reserved
AJ65VBTCU-68ADIN
Ver. 1 remote device station
0: Normal mode
(Ver. 1 compatible slave
1: Test mode (user range setting)
station)
Ver. 2 remote device station
3: Normal mode
(Ver. 2 compatible slave
4: Test mode (user range setting)
station)
2, 5 to 7: Reserved
MELSEC-A