MODBUS MEMORY MAP
Address
Description
1954
Source 6 Ground Current RMS
1956
Source 6 Ground Current Magnitude
1958
Source 6 Ground Current Angle
1959
Source 6 Zero-Sequence Current Magnitude
195B
Source 6 Zero-Sequence Current Angle
195C
Source 6 Positive-Sequence Current Magnitude
195E
Source 6 Positive-Sequence Current Angle
195F
Source 6 Negative-Sequence Current Magnitude
1961
Source 6 Negative-Sequence Current Angle
1962
Source 6 Differential Ground Current Magnitude
1964
Source 6 Differential Ground Current Angle
1965
Source 6 Current Reserved (27 items)
Voltage metering (read-only actual values, six modules)
1A00
Source 1 phase AG voltage RMS
1A02
Source 1 phase BG voltage RMS
1A04
Source 1 phase CG voltage RMS
1A06
Source 1 phase AG voltage magnitude
1A08
Source 1 phase AG voltage angle
1A09
Source 1 phase BG voltage magnitude
1A0B
Source 1 phase BG voltage angle
1A0C
Source 1 phase CG voltage magnitude
1A0E
Source 1 phase CG voltage angle
1A0F
Source 1 phase AB or AC voltage RMS
1A11
Source 1 phase BC or BA voltage RMS
1A13
Source 1 phase CA or CB voltage RMS
1A15
Source 1 phase AB or AC voltage magnitude
1A17
Source 1 phase AB or AC voltage angle
1A18
Source 1 phase BC or BA voltage magnitude
1A1A
Source 1 phase BC or BA voltage angle
1A1B
Source 1 phase CA or CB voltage magnitude
1A1D
Source 1 phase CA or CB voltage angle
1A1E
Source 1 auxiliary voltage RMS
1A20
Source 1 auxiliary voltage magnitude
1A22
Source 1 auxiliary voltage angle
1A23
Source 1 zero-sequence voltage magnitude
1A25
Source 1 zero-sequence voltage angle
1A26
Source 1 positive-sequence voltage magnitude
1A28
Source 1 positive-sequence voltage angle
1A29
Source 1 negative-sequence voltage magnitude
1A2B
Source 1 negative-sequence voltage angle
1A40
Source 2 phase AG voltage RMS
1A42
Source 2 phase BG voltage RMS
1A44
Source 2 phase CG voltage RMS
1A46
Source 2 phase AG voltage magnitude
1A48
Source 2 phase AG voltage angle
1A49
Source 2 phase BG voltage magnitude
1A4B
Source 2 phase BG voltage angle
44
Range
Units
0 to 999999.999
A
0 to 999999.999
A
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
---
---
0 to 999999.999
V
0 to 999999.999
V
0 to 999999.999
V
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
0 to 999999.999
V
0 to 999999.999
V
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
0 to 999999.999
V
0 to 999999.999
V
0 to 999999.999
V
-359.9 to 0
°
0 to 999999.999
V
-359.9 to 0
°
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
---
F001
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0