Toshiba strata DK8 Installation Instructions Manual page 142

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

-.
INSTALLATION-PERIPHERALS
SECTION lOO-816-207
MARCH1993
25PAI R
SEE
PROGRAM 77-1,
LED 07,20
I
FOR RELAY OPTIONS
NOTE:
I
I
I
Unlock Door 0
assigned
to digital and electronic
telephones
in Program
39 with
Code 71.
PIOUS
MDF
Kl/Pi 0 (24VDC, 1 .O AMP MAX.)
TO DOOR LOCK
8-23
. TERMINAL
ON FRONT EDGE OF PCB
FlGURE7-8
DK16 DOOR LOCKCONTROL OPTlON(PIOU/PIOUS)
programmed
to activate continuously
when the Night
Transfer
1 button (only) is set to NIGHT mode (for
indirect answering
machine
control); or to pulsate at
1 -second ON/3-seconds
OFF (for a night bell) when
incoming
CO lines night ring over external
page
(Program 78-13)
(NTI
= tenant 1 CO lines; Nl2
=
tenant 2 CO lines) per
Program 15.
3.33
When configured
for the Music-on-Hold
func-
tion with
Program
77-1,
the relay activates
any
time a CO line is on hold. In this configuration,
the
relay is normally
used to control the Music-on-Hold
source.
3.34 DK16 Night Transfer Relay Control.
Con-
figure the PIOU or PIOUS for the Night Transfer
Relay
function
in accordance
with the following
steps (refer to Figures
7-6 and 7-7):
1)
Access
Program 77-1.
Set
LED 05
to OFF to
configure
the Night/Hold
Relay for the Night
Relay function.
2)
Access
Program 77-1.
Set
LED
06 to provide
continuous
or pulsating
relay activation
as
follows:
l
OFF-Programs
the relay for continuous
activation
when NTI
button (only) is set.
l
ON-Programs
the relay for pulsating
activation
when the NTI
or NT2
button
is set to NIGHT
mode and a tenant
1 or
tenant
2 CO line rings.
NOTE:
CO lines must be enabled
in Program
78-13
for the NT pulsating
relay function.
3)
Access
Programs 87, 88,
and 89 to set the
CO lines that will activate
the relay (when the
system
is in the NIGHT
mode).
4)
Access
Program
39 to program
a Night
Transfer
button
(NT1
or NT2)
on all tele-
phones that are to transfer the system into the
NIGHT
mode.
7-10