3.10 DK8 KSU and DK16 Base Unit Relay
3.11 The DK8 KSU or DKI 6 Base Unit Relay can be
programmed
for one of three options:
l
BGM mute
l
Night transfer
l
MOH source control
These
options
are set in Program
77-l
(LED 01
and 02). Only one option is allowed
per installation.
However,
in the
DK16,
these
options
can
be
supplemented
with
PIOU/PIOUS
relay options.
Refer to Chapter
8 for wiring/interconnecting
de-
tails. Electrical specifications
for the relay contacts
are as follows:
Voltage
l
24VDC
maximum
Current
l
1 ampere
maximum
l
Normally
open-closed
when activated
3.20 DK16 Expansion
Unit PIOU and PIOUS
Relays
3.21 The Expansion
Unit via the PIOU or PIOUS
provides
two additional
relays that control periph-
eral options
(see Figures 7-6,7-7,8-23,
and 8-25).
l
Door Lock Relay/BGM
mute
l
Night Transfer/Music-on-Hold
Relay
NOTE:
The above relay options are available
in con-
junction
with the Base Unit relay option.
3.22 Each relay may be configured
as normally
open (make) or normally
closed (BREAK).
Electri-
cal specifications
for the relay contacts
are as
follows:
Voltage
l
24VDC
maximum
Current
l
1 ampere
maximum
CAUTION!
Do not connect relays direct/y to 12OVAC
power source.
3.23
Door
Lock Control
(PIOU or PIOUS).
Con-
figure the PIOU or PIOUS for the door lock control
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
function in accordance
with the following steps (refer
to Figure 7-6 and 7-7):
NOTE:
Only one door lock control is available using an
optionalintertace
PCB (PIOU or PIOUS), bemuse
only one interface PCB is allowed.
1)
2)
3A)
3B)
4)
Access Program
77-l. Set LED 07 for the door
lock control function.
Access Program 77-l. Set LED 20 to OFF for a 3-
second door lock activation time, or set LED 20 to
ON for a 6-second door lock activation time.
Set the PI0 jumper
plug on the PIOU to the
MAKE or BREAK
position,
as required:
l
MAKE-Shorts
the normally
open con-
tacts (pins 7 and 32) when
a station's
door lock button
is pressed.
l
BREAK-Opens
the
normally
closed
contacts
(pins 7 and 32) when a station's
door lock button is pressed.
Solder the WI jumper plug on the PIOUS to the
MAKE or BREAK position as required:
l
MAKE-Shorts
the normally
open con-
tacts (DET and DER) when
a station's
door lock button is pressed.
l
BREAK-Opens
the
normally
closed
contacts
(DETand
DER) when astation's
door lock button
is pressed.
Refer to Figure 7-8 for wiring/interconnecting
details.
Connect
the PIOU or PIOUS to the
MDF
as required
for the door lock control
function.
3.24
DK8 and DK16 DDCB Door
Lock Control.
In addition
to the door lock control provided
by the
PIOU or PIOUS (DK16 only), each door phone/lock
control
box (DDCB)
installed
provides
one door
lock control. Only two DDCBs can be installed
in a
system:
On DK8 a DDCB
can be connected
to
Circuit
3 (Port 02) and/or
Circuit 4 (Port 03); on
DK16 a DDCB
can be connected
to the circuit 5
(Logical
Port 04) of the Base Unit Digital telephone
circuit set and to circuit 1 of the KCDU
or PDKU