Selecting/Creating Operand Forms For Plc Status - Siemens SINUMERIK 840D Operator's Manual

Computerized numerical control system for machine tools
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

8
Diagnosis Operating Area
8.4 PLC
Delete
Abort
Accept

8.4.3 Selecting/creating operand forms for PLC status

8-292
Delete:
The entries for the selected operand (formats and values) are deleted.
A query window is opened.
Undo changes:
Press the "Abort" softkey.
Cyclic updating is continued; the entered values are not transferred to
the PLC.
Accept:
The entered values are transferred to the PLC. Cyclic updating is
continued.
Further information
Press the "Information" key.
A description of the permissible input syntax for the PLC status
display is overlaid.
Function
You can save the operands entered in the "PLC status" window to a
file or read in a back-up list of operands.
The values in the PLC status are automatically discarded when the
system is restarted cold (after POWER ON).
As a way of optimizing the entry of operands and formats in the PLC
status, you can read in operand screen forms from DOS files (one file
for each screen form).
These screen forms are generated in a special syntax in ASCII
format.
Naming conventions for DOS files:
name.plc
Content of the DOS file:
[\\Comment]
Operand/Format
[Operand/Format]
.
.
[Operand/Format]
SINUMERIK 840D/810D Operator's Guide HMI Embedded (BEM) – 03.04 Edition
name is a screen form name of max.
8 characters
e.g.//form for the PLC test
DB0.DBB0/B
DB1.DBW0/H
.
.
T100-D
 Siemens AG, 2004. All rights reserved