Connection methods

6.2 Power connection

6.2
Power connection
Connecting motors
Note
The motors can be fed from a DC link voltage of up to 700 V DC.
Table 6- 1
Overview, connection system for 1PH4 motors
SH
Number
Main terminals
100
3 x M5
132
3 x M5
160
3 x M10
Carefully observe the current which the motor draws for your particular application!
Adequately dimension the connecting cables according to IEC 60204-1.
Power cable
Figure 6-2
118
Max. cross-section that can be
connected
16 mm
2
35 mm
with cable lug
2
connection
70 mm
with cable lug
2
connection
CAUTION
Power cable
Terminal strip for
PE connection size/
temperature sensor
cable lug width
3 terminals
M4/9 mm
3 terminals
M5/15 mm
3 terminals
M6/15 mm
Configuration Manual, (APH4S), 08/2008, 6SN1197-0AD64-0BP1