c) Secondary scanning reproduction ratio
(1) Confirm that the value of the cutting volume of the scanner leading image edge (code 313) is
128 (default value).
0
5
3
PWR
(2) Place the scale (horizontal to the copy movement direction) and make an A3 100% copy.
(3) Compare the copy and the scale.
(4) In order to adjust the divisions of the scale, do as follows.
0
5
3
PWR
Notes 1. An increase in the value corresponds to an increase in the division of scale (0.1522
%/step).
2. In order to make a test copy, make sure the message indicates [ 100 %
after the INT key is pressed.
3. Adjustment value is able to be input within the range of 0 ~ 255.
The default adjustment value is 128.
September 1997 © TOSHIBA CORP.
1
3
START
Copy movement direction
Copied Scale
Actual Scale
0
4
START
1 - 33
In case the value is "128".
In case that the value is not
"128", input "128" with the
digital keys
Set the value
INT
INT
PWR OFF
E/S
(Test copy)
A ]
2460 ADJUSTMENT