Warning messages
Message on the display
Oil temperature too high.
Machine speed has been
reduced and tool is disabled.
Oil temperature too low.
Machine speed has been
reduced and tool is disabled.
Oil pressure is above
allowed limits. Please check
proportional pressure relief
valve.
Overloading when soft
starting. Check the input
voltage and soft start
settings.
Phase error. Please check:
Incoming phases
Incoming voltages
Machine speed has been
reduced and tool is disabled.
Motor temperature too high.
Machine speed has been
reduced and tool is disabled.
No hydraulic pressure
detected. Please check:
Oil level
Motor rotation
Check Emergency Stop on
machine and safety relay
function.
Terminal lost for more than
120 seconds
Oil pressure in circulation
pump mode too high. Please
check circulation valve
48 –
English
TROUBLESHOOTING
Indication on the
Effect on machine
machine
functions
Flashes with the
work lighting and
puts the machine in
The machine
circular pumping
deactivates the tool
mode. The motor is
and reduces the
shut down if the
machine speed with
message is not
50%.
acknowledged
within 10 sec.
The engine is
switched off.
Flash with the work
lighting.
Prevents starting of
the machine.
Cause
Possible action
Put the machine into circular
pumping mode to cool the
hydraulic oil.
The oil temperature
Clean the cooler
is above 90°C
Clean the cooler fan
Check the sensor and cables to
the sensor.
Allow the machine to warm up
slowly. Warm up the lower
section by running the caterpillar
tracks, first slowly and then more
The oil temperature
quickly with the outriggers
is below -5°C
extended.
Check the sensor and cables to
the sensor.
Check proportional pressure
relief valve.
Oli pressure
exceeds allowed
Verify pressure regulator by
pressure limit.
running a cylinder to end position
for 2 seconds.
Overload protection
Check the input voltage and the
alarm in soft starter.
soft starter settings.
Phase error in
incoming 3 phase
Check the voltage level of the
and the motor
incoming phases, or if a phase
temperature is too
has been lost.
high.
High motor
Allow the circulation pump to run
temperature
and wait for the temperature to
detected
drop.
Check if the pump produces
Warns if the
pressure.
pressure sinks
below 2 bar when
Check hydraulic fluid level
the motor is
Check if the motor runs in the
running.
correct direction.
Emergency stop
Check the emergency stop on
pressed on the
the machine.
machine, faulty
Check bypass signal from
safety relay, safety
softstart
relay control circuit
Check safety relay and its safety
open or no bypass
circuit
signal from
Check start relay
softstart.
The machine has
The machine flashes 3 times
not been in contact
when the message is
with the remote
acknowledged.
control for 2 min.
The oil pressure in
Check the circulation pump valve
circulation pumping
(idle valve)
is too high.