Advertisement

OBJ_BUCH-1625-001.book Page 1 Thursday, July 5, 2012 9:22 AM
WEU
Robert Bosch GmbH
Power Tools Division
70745 Leinfelden-Echterdingen
Germany
www.bosch-pt.com
2 609 140 909 (2012.07) T / 88 WEU
WEU
PTD 1
de Originalbetriebsanleitung
en Original instructions
fr
Notice originale
es Manual original
pt Manual original
it
Istruzioni originali
nl Oorspronkelijke gebruiksaanwijzing
da Original brugsanvisning
sv Bruksanvisning i original
no Original driftsinstruks
fi
Alkuperäiset ohjeet
el Ðñùôüôõðï ïäçãéþí ÷ñÞóçò
tr
Orijinal işletme talimat
ar

Advertisement

Table of Contents
loading

Summary of Contents for Bosch PTD 1

  • Page 1 OBJ_BUCH-1625-001.book Page 1 Thursday, July 5, 2012 9:22 AM Robert Bosch GmbH Power Tools Division 70745 Leinfelden-Echterdingen PTD 1 Germany www.bosch-pt.com 2 609 140 909 (2012.07) T / 88 WEU de Originalbetriebsanleitung sv Bruksanvisning i original en Original instructions no Original driftsinstruks Notice originale Alkuperäiset ohjeet...
  • Page 2 OBJ_BUCH-1625-001.book Page 3 Thursday, July 5, 2012 8:56 AM 2 607 990 031 c d e f PTD 1 Bosch Power Tools 2 609 140 909 | (5.7.12)
  • Page 3 OBJ_BUCH-1625-001.book Page 4 Thursday, July 5, 2012 8:56 AM 2 609 140 909 | (5.7.12) Bosch Power Tools...
  • Page 4: Safety Notes

    (e.g. heavily reflecting n Unit of measure for temperature measurements or transparent materials) can lead to faulty measuring o Error warning results. p Battery low indicator Bosch Power Tools 2 609 140 909 | (5.7.12)
  • Page 5: Inserting/Replacing The Battery

    OBJ_BUCH-1625-001.book Page 12 Thursday, July 5, 2012 8:56 AM 12 | English Technical Data Thermo detector PTD 1 Article number 3 603 F83 000 Measuring range – Surface temperature –20...+200 °C – Ambient temperature –10...+40 °C – Relative humidity 10...90 %...
  • Page 6: Initial Operation

    Allow the tape to briefly acclimatize to the surface. be checked and if required, adapted to the object being meas- On condition of the principle, taking measurements through ured prior to each measurement. transparent materials is not possible. Bosch Power Tools 2 609 140 909 | (5.7.12)
  • Page 7: Measuring Functions

    Upon completion of the measurement, the measured surface completion of the measurement, the measured relative hu- temperature is displayed in line l. midity is displayed in line b, the measured ambient tempera- 2 609 140 909 | (5.7.12) Bosch Power Tools...
  • Page 8: Troubleshooting - Causes And Corrective Measures

    If the error continues, have the measuring tool checked by an surface temperature, or because the humidity is too high. authorised Bosch after-sales service. The flashing symbol for relative humidity d indicates too high humidity in the room,...
  • Page 9 If the measuring tool should fail despite the care taken in man- ufacturing and testing procedures, repair should be carried Gauteng – BSC Service Centre out by an authorised after-sales service centre for Bosch pow- 35 Roper Street, New Centre er tools. Do not open the measuring tool yourself.
  • Page 10 Tel.: +66 (2) 6 31 18 79 – 18 88 (10 lines) Tel. Service: +44 (0844) 736 0109 Fax: +66 (2) 2 38 47 83 Fax: +44 (0844) 736 0146 Robert Bosch Ltd., P. O. Box 2054 E-Mail: boschservicecentre@bosch.com Bangkok 10501, Thailand Subject to change without notice.