Download Print this page

Bosch DCN Next Generation 4.41 Release Notes page 11

Advertisement

DCN Next Generation Release Notes
Product/function
DCN-SWWA
DCN-SWWA
DCN-SWWA
DCN-SWWA
DCN-SWWAEC
DCN-SWWAEC
Not all text is
shown on
Webcasting player
Wireless system in
combination with
Integrus
Not able to
download DCN-
CCU2 firmware
HD Conference
Dome
DCN-UPTK
Bosch Security Systems| 2014-10-31
Problem
Does not work with
DCN-SW
Webcast will stop
after 12 hours.
No audio on SDI input
box
Opinion Poll and
Multiple Choice
information from
DCN-SWSMD is not
supported.
Slave languages not
added after using
Refresh function.
Webcast will not start
on slave PC's.
For security reasons,
all text between the
signs '<'and '>' is
removed and currently
not shown on the
webcasting player
website.
No audio on DCN
wireless units when
powering up DCN-
CCU2 and Integrus
transmitter
simultaneous.
DCN-DLT is not able
to download the
firmware of the CCU
The HD Conference
Dome will show an
incorrect name &
picture combination if
a new pre-position is
asked before it
reaches it's pre-
position.
The type of the unit
connected to the
UPTK is not valid.
Solution
DCN-SWWA 1.1.1 requires DCN-SW 4.2x or later
DCN-SWWA 1.0.1 requires DCN-SW 4.1x
Maximum webcast length of a webcast is 12 hours. It
will stop automatically.
With setup, please note if there is no audio, resetting
the Audio to SDI box most of the time will solve the
problem.
none
Refresh webcast will only effect PowerPoint slides.
Load webcast will add the languages
Close the publisher on slave PC's before starting a
new webcast.
Do not use the "<" and ">" characters in DCN-SW
(e.g. meeting information, session information, voting
information, delegate names) or Webcast Planner
Website.
First power up the DCN-CCU2. After it is powered up,
power up the Integrus transmitter.
Check if the DCN-SW server is not running:
1. Exit the DCN-DLT program
2. Check if the DCN-CCU2 does not report PC
on it's display. If it does Stop the DCN-SW
server via Start\ <Search programs and files>
SERVICES. Services (local). And check if PC
disappears.
3. Start DCN-DLT (PC will now re-appear in the
CCU2 screen, but that is correct) and start
the download.
If the download still fails, do the following:
1. Power off and open the DCN-CCU2
2. Set switch 8 of S600 to ON and power on the
CCU.
3. Download the CCU using the DCN-DLT.
4. After a succesfull download, power off the
CCU, set switch 8 of S600 to OFF again and
power on the CCU.
Do not activate another microphone until the HD
Conference Dome has reached it's pre-position.
This notification can occur when the DCN-UPTK unit
is used extensively. Please replace the connection
cable.
en | 11

Hide quick links:

Advertisement

loading