DCN Next Generation Release Notes
Product/function
DCN-SW
DCN-SW
DCN-SW
DCN-SW
DCN-SW
DCN-SW
DCN-SWPV
DCN-SWPV
DCN-SW setup
repair
DCN-SWSMV
DCN-SWSMV help
file
DCN-SWSMV
Bosch Security Systems| 2014-10-31
Problem
On 64-bit operating
systems, it might
difficult to find
previous SQL-server
during DCN-SW
installation, when
initial SQL-installation
was not default.
System overview
does not show all
connected devices
when system is still
powering up.
DCN-SW Master
Volume is different
from CCU volume
control
Downgrade to
versions <3.10 not
possible.
Unexpected
behaviour or no
reaction of DCN-SW.
Generates errors after
Windows Stand by..
Secret mode does not
work in ad-hoc voting
Voting attention tone
cannot be changed
during a running
meeting.
Error code 2869 or
Fatal error during
installation.
Error notification upon
closing DCN-SWSMV
directly after opening
it.
When opening help
file you get an error.
DCN-SWSMV will not
start
Solution
During installation of DCN-SW the installation process
might not be able to find the previous SQL-server, in
case during initial installation another name for the
SQL-server was created, instead of using the default
name. Therefore it is recommended to use the default
name and folder during initial SQL-installation. If a
SQL-server with a non-default name needs to be
found, the correct name should be entered manually
in the applicable box during DCN-SW installation.
Wait until DCN-system is powered up completely and
then check the connected devices via DCN-SW
configuration application VIEW \ System Overview.
When the Master Volume of the CCU has been
changed while DCN-SW was disconnected, the DCN-
SW Master Volume will not reflect the CCU-setting.
Changing the DCN-SW volume setting, will make
them identical again.
Manually uninstall SWL server 2008.
Note that the DCN-SW database (the database
contains all settings like seats, meetings, synoptic
layouts, etc.) will always be removed during a
downgrade.
Due to Windows Automatic Updates some critical
components like SQL Server Express might be
temporarily not available for DCN-SW.
Do not set Automatic Updates to Automatic or restart
your system after the Automatic updates have been
installed.
Disable Stand by functionality in the Windows
operating system.
Update to version 2.80 or higher
The voting attention tone can be changed in the
voting template but becomes effective after a vote has
been selected or started.
Remove DCN-SW with DCN-SW setup and make a
new installation. Settings are stored in the SQL-
database and can be re-used in the new installation.
Please wait at least 10 seconds to close DCN-
SWSMV after opening it.
Just close the error notification.
Voting legends cannot be changed into "Not Voted".
Remove "BCPCSettings.xml" which can be found:
For XP:
"...\Documents and Settings\All Users\Application
Data\Bosch\DCN Synoptic Microphone and Voting
Software\x.xx"
For Vista:
"...\Programdata\Bosch\DCN Synoptic Microphone
and Voting Software\x.xx"