(5) Release the lock, and disconnect the LCD flat cable from the panel PCB ASSY.
(6) Disconnect the back light harness from the panel PCB ASSY.
Back light harness
Panel PCB ASSY
(7) Release the ten hooks (six for DCP models), and remove the panel PCB ASSY from the
control panel ASSY.
Panel PCB ASSY
Hooks
Lock
Fig. 3-73
Hooks
Control panel ASSY
Hooks
Fig. 3-74
3-57
LCD flat cable
Hooks