Operation
6.2.2.2
Parameterization Menu
In the parameterization menu, you can adjust the cabinet unit settings.
Parameters are also arranged in function groups so that you can find them more
easily. You can, however, call up a list displaying all the parameters.
In both cases, the parameters displayed depend on the access level that has been
set. You can set the access level in the menu for inhibit functions, which you can
call up by pressing the key pushbutton.
6.2.2.3
Menu Settings
Selecting Data Sets
In this menu, you select the active data set for displaying and processing
parameters which, although relevant to both REMOTE mode 0 and 1, can be set
differently.
For example, the main setpoint for terminal operation (p1070[1], REMOTE mode 1)
and the main setpoint for PROFIBUS operation (p1070[0], REMOTE mode 0) can
be set via two separate command data sets.
The command data set that must be activated for setting the relevant main setpoint
is indicated in square parentheses [].
In the factory setting, command data set 1 is active.
Control Settings
This defines the settings for the control keys in LOCAL mode.
See Section 6.2.3.
Display Settings
In this menu, you set the lighting, brightness, and contrast for the display.
Defining the Operation Screen
In this menu, you can switch between four operation screens. By pressing F3 –
"Values", you can set the parameters that are to be displayed.
6-6
11/03
SINAMICS G150
Operating Manual