Bosch 2600 Series Instruction Manual page 18

System4 video controllers command console language
Table of Contents

Advertisement

LTC 2600 Series | Instruction Manual | Multiplexer Set (MS) Commands
MS-MON-TIME-ENABLE <monitor> <boolean>
This command enables or disables time/date display
for the specified monitor.
Parameter values for <monitor> and <boolean> are:
<monitor>
1
2
<boolean>
0
1
MS-MON-TIME-POSITION <location>
This command sets the time/date display row position
for any enabled monitors and for both small and large
text. The specified row value is converted into one
corresponding to bottom, middle, or top of the screen.
Parameter values for <location> are:
0
1
2-31
5-33
MS-OPERATION <operation>
This command sets the current system operation mode
to the specified mode. The system will reject any value
that is not compatible with the current configuration
(i.e. simplex/ duplex, standard/System4).
Parameter values for <operation> are:
3
4
5
6
7
8
Bosch Security Systems | July 12, 2004
Monitor A
Monitor B
Disables
Enables
Time/date display OFF
Time/date display ON
(NTSC) Display row position
(PAL) Display row position
live
record
playback
playback-record (duplex and
duplex/System4 only)
record-record
(duplex/System4 only)
playback-playback
(duplex/System4 only)
MS-OPERATION-SIMPLEX <mode>
This command sets the operating mode for simplex
multiplexer models.
Parameter values for <mode> are:
1
2
3
NOTE: Delay slightly when sending multiple MS-
OPERATION-SIMPLEX commands (about .1 sec.) to
avoid getting an error message stating that the
keyboard is busy (it may be busy processing an earlier
command).
MS-OPERATION-DUPLEX <mode-D1> <mode-
D2>
This command sets the operating mode for duplex
multiplexer models.
Parameter values for <mode-D1> and <mode-D2>
are:
<mode-D1>
1
2
4
<mode-D2>
0
1
NOTE: Delay slightly when sending multiple MS-
OPERATION-DUPLEX commands (about .1 sec.) to
avoid getting an error message stating that the
keyboard is busy (it may be busy processing an earlier
command).
For new applications, use the MS-OPERATION
command instead of this one.
MS-PASSWORD <password> <password>
<password>
This command changes the password in the
multiplexer. The first parameter is the old password.
The second and third parameters are the new
password value (repeated). The command is rejected if
the first parameter is not the same as the unit's current
password, or if the second parameter is not the same as
the third parameter.
EN | 18
Monitor A - live digital,
record OFF
Monitor A - decoding, record
OFF
Monitor A - live analog,
record ON
Monitor A - live digital
Monitor A - playback
Record ON - System4
models only
Record OFF
Record ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltc 2600 series

Table of Contents