13 Configure the alarm settings [Alarm]
[Post alarm (recording) duration]
Set the duration to save image data on the SD memory card after an alarm occurrence.
10s/ 20s/ 30s/ 40s/ 50s/ 60s/ 120s/ 180s/ 240s/ 300s
Default: 30s
* The actual recording time may sometimes be longer than the duration selected for this setting.
[Recording (memory) size per an alarm]
The capacity of the SD memory card used to record video data upon an alarm occurrence. The actual capacity
may be different.
IMPORTANT
To record H.264 data, it is required to select "Use" for "SD memory card" on the [SD memory card] tab.
In addition, it is required to select "H.264" for "Recording format". (®page 54)
13.5 Configure the settings relating to the alarm
output terminal [Alarm]
Click the [Alarm] tab on the "Alarm" page. (®page 43, page 45)
The settings relating to the alarm output terminal can be configured in this section.
Alarm output terminal setup
[Alarm output trigger]
Select "On" or "Off" to determine whether or not to output the alarm signals to the alarm output terminal when
an alarm is detected.
Default: Off
[Alarm output type]
Select "Latch" or "Pulse" for the alarm output terminal at an alarm occurrence.
Latch: When an alarm is detected, the alarm output terminal will be in the state selected for "Trigger
output" until the alarm occurrence indication button is clicked.
Pulse: When an alarm is detected, the alarm output terminal will be in the state to the "Trigger output"
setting for the period set for "Pulse width". When the alarm occurrence indication button is clicked, the
alarm output terminal will return to the normal state.
Default: Latch
[Trigger output]
Select "Open" or "Close" to determine whether to open or close the alarm output terminal when outputting the
alarm signals.
Open: The alarm output terminal will open when outputting the alarm signals. (Normally close)
Close: The alarm output terminal will close when outputting the alarm signals. (Normally open)