HP OMNIBER 718 37718A User Manual page 67

Dsn/sonet operation
Table of Contents

Advertisement

N OT E
Pointer Sequence
T1.105 A1 SINGLE
GR-253 5-29
T1.105 A2 BURST OF 3
GR-253 5-30
Selecting Test Features
Adding Pointer Adjustments
The following conditions apply for pointer sequence generation:
The sequences can only be applied to the SPE pointer when the SPE does
not contain a VT structure, otherwise it is applied to the VT pointer.
Pointer sequence generation is not available when a frequency offset is
being applied to the Line Rate.
The following figure gives an example of a T1.105/GR-253, 87-3 Pointer
Sequence.
T1.105 A4 and A5, 87-3 Pattern
Pointer Adjustment
An Example of a Pointer Sequence
Periodic Single adjustments, all of the same polarity which is
selectable. Separation between pointer adjustments is fixed at
approximately 30 seconds.
Periodic bursts of 3 adjustments, all of the same polarity which is
selectable. The interval between bursts is fixed at approximately 30
seconds. The interval between adjustments within a burst is set to
the minimum.
No Pointer
Adjustment
87
Description
Start of Next
87-3 Pattern
3
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

37718a omniber 718

Table of Contents