Field
Description
Downstream ID
A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the set-top.
0000 is displayed if the Downstream ID is not configured or unknown.
State
Indicates the interactive status of the set-top:
LED
U
C
I dc
I L
I SO
I LA
S I
r dc
r
S
00
MAC Abort Cntr
This counter increments every time the MAC layer reaches the cell abort count limit. It is
reset by the successful upstream transmission of a cell, for example, when the set-top
receives an ACK. If the counter reaches the MAC abort count limit, the set-top assumes
the MAC layer is unavailable due to noise, congestion, or some other problem. The
set-top stops transmitting data upstream, reports an error to the calling function, and
attempts to re-enter the network using the initialization process. 0000 is displayed as
default or if the MAC Abort CNTR is not configured or unknown.
Socket Port State
Indicates the socket mode and activity:
UNUSED — The socket is not being used.
OPENED — The socket is open.
READY — The socket is ready to send or receive.
RECEIVING — The socket is receiving data from the application server.
SENDING — The socket is sending data to the application server.
UNKNOWN — The socket state is invalid or unknown.
OSD
UNCONFIG
MAC_CONNECT
INIT_WAIT_DC_OR_C
WAIT_LM_ACK
WAIT_SO_ACK
WAIT_LA_OR_SO
INIT_STOPPED
RUN_WAIT_DC_OR_C
RUNNING
RUN_STOPPED
INVALID
Description
The set-top is not configured for the interactive system
and platform should run as pre-interactive.
The set-top is waiting to establish connection to MAC
PID Stream.
The set-top is running in the interactive initialization
state and waiting for the default configuration or the
contention channel list messages.
The set-top is running in the interactive initialization
state and waiting for Link Management Response ACK
for Local Address Message.
The set-top is running in the interactive initialization
state and waiting for a Sign On acknowledgement.
The set-top is running in the interactive initialization
state and waiting for Logical Address or Sign On with
verification Frequency message.
The set-top is in the interactive initialization state and
the TransMode has stopped.
The set-top is running in the interactive state and
waiting for the default configuration or the contention
channel list messages.
Interactive state is running, sending idle messages,
and waiting for any prepare for poll or MAC messages.
The interactive run state has stopped and set-top is
waiting for status or transmission control message.
Set-top interactive state is unknown or invalid.