3.10.2 Modem Setup

Siemens Building Technologies
Fire & Security Products
The factory default LAN settings are:
DHCP:
Off
IP Address:
192.168.1.129
Gateway:
192.168.1.254
Subnet Mask: 255.255.255.0
The factory default IP Port settings are:
Admin:
8200
Watch:
8016
Search:
10019
Callback:
8201
NOTE:
Do NOT use the same IP port number for two different programs; otherwise, the DVR cannot be
connected with a PC running RAS.
When changing the IP port settings, you must change the IP port settings on a
CAUTION
PC running RAS as well. Refer to the RAS manual for details.
You can save your changes and return to the Network Setup screen by highlighting
OK and pressing the
the changes.
Fig. 62
RS232/RS485 setup screen.
NOTE:
Modem setup is done through the RS232/RS485 screen in the Devices menu, which can be accessed
from the Main Menu.
NOTE:
If the RS232 port is in use for the remote control, the networking cannot be configured by the modem.
In the RS232/485 Setup menu, set up the RS232 port to communicate with the external modem first.
button . Selecting Cancel exits the screen without saving
Configuration
59
SISTORE AX9 AX16_EN.doc
09.2004