7.9. Switching operation (1) from the fixed scan mode to the sheet scan mode
Sheet scan drive side gear train
Scan unit drive side gear train
Planet gear B
System gear biasing spring
When the scan unit's lever that comes back to the sheet scan position
pushes the system gear pin, the system gear starts rotating in clock-
wise direction.
7.10. Switching operation (2) from the fixed scan mode to the sheet scan mode
Scan unit drive side gear train
Planet gear B
Due to the system gear rotation, the pin B on the planet gear mounting
arm is guided in the cam groove B, and the planet gear B is engaged
with the system gear. Along with the system gear rotation, the scan
unit locking lever moves toward the lock position.
Planet gear A
Sheet scan drive side gear train
Planet gear A
Pin A
Cam groove A
System gear biasing spring
Pin
Motor gear
(drive source)
Counterclockwise rotation: The scanner
unit moves toward the sheet scan position.
System gear
Pin
Scan unit locking lever
Motor gear
(drive source)
Counterclockwise rotation: The scan
unit moves toward the sheet scan position.
Cam groove B
Pin B
System gear
Lever
Scan unit locking lever
3 – 8
Scanner unit
Lever
Scanner unit
AM-900U