AM-900U
5. Soft switch description
5.1. Soft switch
SW
DATA
NO.
NO.
1
Recall interval
2
3
4
SW1
5
Recall times
6
7
8
1
Memory retransmission times
2
3
4
SW2
5
Memory retransmission interval
6
7
8
1
Number of rings for auto-receive
2
(0: No ring receive)
3
4
SW3
COPY/FAX/SCAN mode
5
6
7
Receive mode
8
Reserved
ITEM
No. 5
No. 6
AUTO
Switch setting and function
1
Binary input
No. = 8
4
2
1
1
2
3
4 (Data No.)
EX 0
1
0
1
eg. Recall interval is set 5 min.
Binary input
No. = 8
4
2
1
5
6
7
8 (Data No.)
EX 0
0
1
0
eg. Recall times is set 2 times
Binary input
No. = 8
4
2
1
1
2
3
4 (Data No.)
EX 0
0
0
1
eg. Retransmission time set to 1 time.
Binary input
No. = 8
4
2
1
5
6
7
8 (Data No.)
EX 0
0
1
0
eg. Retransmission interval to 2 minutes.
Binary input
No. = 8
4
2
1
1
2
3
4 (Data No.)
EX 0
0
0
1
eg. Number of rings for auto receive is set to 1.
COPY
FAX
SCAN
0
0
1
0
1
0
MANUAL
2 – 16
Initial setting
0
U
0
1
0
1
0
0
1
0
0
0
0
1
0
0
1
0
0
0
0
1
SCAN
1
0
0
1
1
0
Remarks