Fujitsu PRIMERGY RX200 S2 User Manual page 71

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Hexad
ecimal
ID
Type
notatio
n
802
(0x322)
Warn
ing
803
(0x323)
Warn
ing
804
(0x324)
Warn
ing
805
(0x325)
Warn
ing
806
(0x326)
Infor
mati
on
807
(0x327)
Infor
mati
on
808
(0x328)
Infor
mati
on
896
(0x380)
Error
Log item
Configuration
The array configuration
Invalid.
information is invalid.
Configuration On
The array configuration
Disk Access Error.
information could not
be read from the hard
disk.
Configuration On
COD was converted.
Disk Converted.
Configuration On
The array configuration
Disk Import Failed.
information could not
be imported.
A Debug Dump
exists on this
system.
A debug dump exists in
the system.
A Debug Dump
exists on this
system.
No valid
The configuration
Configuration On
information in a hard
Disk (COD) found.
disk is invalid.
Internal Controller is
The SCSI array
in the hung state.
controller hung.
Description
Check to see whether the
hard disk is connected
properly.
If the above does not
resolve the issue, recreate
the array and restore the
backup data.
Recreate the array and
restore the backup data.
Not required.
Check to see whether the
hard disk is connected
properly.
If the above does not
resolve the issue, recreate
the array and restore the
backup data.
Not required.
Turn off the server and
check to see whether the
hard disk is connected
properly.
If the error persists after
the above action,
reconfigure the SCSI
array controller and
restore the data.
Replace the SCSI array
controller.
B List of GAM Error Codes