GE ZVC36LSS Installation Instructions Manual page 2

30", 36", 48" custom hood insert
Table of Contents

Advertisement

Installation
Instructions
BEFOREYOU BEGIN
Read these instructions
completelg
and
carefullg.
IM
PORTANT-
Save these instructions for local
inspector's use.
• IMPORTANT-
Observe all governing codes
and ordinances.
• Note to Installer-
Be sure to leave these
instructions with the Consumen
• Note to Consumer - Keepthese instructions for
future reference.
• Skill Level-
Installation of this vent hood
requires
basic mechanical and electrical skills.
• Completion
time - i to 3 hours.
• Proper installation is the responsibilitg of the installer.
• Product failure due to improper installation is not
covered under the Warrantg.
For Monogram
local service in gour area, call
1.800.444.1845.
For Monogram service in Canada, call 1.888.880.3030.
For Monogram
Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of these vent
hoods and to reduce the risk of personal
in]ur U or damage to the product, TWO PEOPLEARE
REQUIRED FOR PROPER INSTALLATION.
ATTENTION'.
A cause du poids et des dimensions du
ces hottes et pour rGduire les risques de
blessures ou de dommages du produit, IL FAUT
DEU× PERSONNES POUR FAIREUNE INSTALLATION
CORRECTE.
WARNING:
To reduce the risk of fire or electrical shock,
do not use this range hood with ang external
solid-state speed control device. Ang such alteration
from original factorg wiring could result in damage to
the unit and/or create an electrical safetg hazard,
AVERTISSEMENT :
Pour r_duire le risque d'incendie ou de
choc _lectrique, il ne faut pas utiliser cette
hotte avec un rGgulateur de vitesse _lectronique
externe. Toute modification de ce tgpe du branchement
d'usine peute endommager
I'appareil ou crGer un risque
de choc 61ectrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
A,
B,
WARNING:To REDUCE
THE RIsK
OF FIRE,ELECTRIC SHOCKOR INJURYTO
PERSONS, OBSERVE THE FOLLOWING:
Usethis unit onlg in the manner intended by the
manufacturer. If you have questions,contact the
manufacturer.
Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentallU.
When the service disconnecting means cannot be locked,
securelUfasten a prominent warning device, such as a tag,
to the service panel.
AVERTISSEMENT:
POURRI_DUIRE LE RISQUED'INCENDIE,
DECHOC ELECTRIOUE O U DEBLESSURES
CORPORELLES, IL FAUTOBSERVER LESREGLES SUIVANTES :
A. Utilisez cet appareil uniquement de la mani_re pr@ue
par le fabricant. En cas de question,consultez le fabricant.
B. Avant tout entretien, r@parationou nettogage, coupez
I'alimentation @lectrique au disjoncteur et verrouillez le
panneau du disjoncteur pour @iter la mise sous tension
accidentelle. S'ilest impossible de verrouiller le panneau
du disjoncteur,attachez solidement une note de mise en
garde tr_s visible,comme une @iquette,au panneau.
CAUTION: For General
Ventilating
Use
OnlU.Do Not UseTo Exhaust Hazardous Or
ExplosiveMaterials And Vapors.
ATTENTION : Utilisezuniquemen
pouruneventilation g_n@rale. N'utilisez paspour
@acuerdesvapeursou desmat@iaux
dangereux ouexplosifs.
WARNING:To REDUCETHE
RiSK
OF FIRE,ELECTRIC SHOCKOR INJURYTO
PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done bg
qualified person(s)in accordance with all applicable codes
and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimneg)of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safetg
standards such as those published bg the National Fire
Protection Association (NFPA), and the American SocietU
for Heating, Refrigerationand Air Conditioning Engineers
(ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling,do not damage
electrical wiring and other hidden utilities.
D. Ducted fans must alwags be vented to the outdoors.
• Local codes varU. Installation of electrical connections
and grounding must compl Uwith applicable codes. In
the absence of local codes,the vent should be installed
in accordance with National ElectricalCodeANSI/NFPA
70-1990 or latest edition.