Conettix Communications Receiver/
Gateway
4 ᅳ Parallel Printer Port.
* Use a null-modem cable to connect directly to the computer. You can also connect this port
to a Network Ethernet Module for communicating over a network.
6.4

Card Removal and Replacement

Warning!
!
Remove power to the D6600 before removing, replacing, or installing the CPU card (D6610)
or CPU terminator card (D6615).
Removing the CPU Card
1.
2.
3.
4.
Replacing the CPU Card
1.
2.
3.
4.
5.
Bosch Security Systems, Inc.
Remove power to the receiver (refer to Removing Power to the Receiver, page 26).
Carefully grasp the plastic grip on the CPU card. Slide it 2 in to 3 in (50 mm to 75 mm)
out of the enclosure.
Unplug the 50-pin ribbon cable connecting the user interface card to the CPU card. Be
careful not to bend the board when disconnecting this cable. Grasp the plastic plug
connected to the CPU board at the end of the cable and gently pull it away from the
circuit board.
Pull the CPU card straight out of the card guide.
Remove power to the receiver (refer to Removing Power to the Receiver, page 26).
Remove the defective CPU card from the enclosure.
Align the top and bottom of the CPU card with the card guides. Slide the card into the
enclosure, leaving 2 to 3 in (50 mm to 75 mm) out to connect the ribbon cable.
Connect the ribbon cable to the CPU card. Orient the cable so the red stripe is up, and
slide the card the remaining distance into the enclosure.
Restore power to the receiver.
Installation and Operation Guide
D6600 Specific Cards | en
2012.11 | 08 | 4998122704
23