4.5.1 Important Considerations
1. To ensure proper Bilinx communications, the
video output of the LTC 4631 Series module
must be terminated into a proper 75 ohm load.
If improper video looping connections are used,
erratic or no camera P/T/Z control may result.
2. Do not exceed the published distance
specification for Bilinx communications. Erratic
or no camera P/T/Z control may result. Refer to
the data sheet for product specifications.
3. Although these modules are compatible with
Bilinx up-the-coax communication technology
found in Bosch Security System products,
compatibility is not guaranteed when used with
similar technologies employed by other
manufacturers.
Typical Configuration:
POWER
Up to 600 m (2000 ft) using
62.5/125 micron
Multimode Fiber Optic Cable
LTC 4631
BILINX/UP THE COAX
VIDEO RECEIVER + DATA TRANSMITTER
VIDEO OUT
AGC LEVEL
AGC
POWER
Figure 4 LTC 4630 Series and LTC 4631 Series Stand-alone Bilinx Transceivers
Bosch Security Systems | July 08, 2008
LTC 4630
BILINX/UP THE COAX
VIDEO TRANSMITTER + DATA RECEIVER
OPTICAL CABLE
AC - 3
- 2
POWER
AC - 1
+12VDC - 1
24VAC CT
+12VDC
VIDEO + Bilinx DATA
OPTICAL CABLE
VIDEO OUT
BLACK
- 2
POWER
+12 VDC - 1
BLACK with
POWER
WHITE
SUPPLY
MARKINGS
4.5.2 Indicators / Operation
1. The POWER LED illuminates when AC power
is applied to the unit.
2. LTC 4631 Series units: Once the video signal
and fiber optic connections have been
completed, the state of the VIDEO OUT and
AGC LED indicators should be examined. If
both are GREEN, test the VIDEO OUT LED
action by temporarily removing the video signal
from the LTC 4630 module. The LED should
turn RED.
If necessary, adjust the AGC control in small
increments until the correct LED actions are
obtained. Marginal signal strengths are indicated
by an AMBER color LED, and a RED LED
indicates video loss, or that further adjustments
are needed. The adjustment is sensitive. Adjust
the control too high, and the VIDEO OUT
LED may remain lit even when the video signal
is removed or lost. If adjusted too low, the
VIDEO OUT LED may remain RED even if a
video signal is present.
VIDEO + Bilinx DATA
VIDEO IN
BLUE
- 2
GREEN
BROWN
POWER
SUPPLY
AC
POWER
TYPICAL ALLEGIANT SERIES SWITCHER/CONTROLLER,
DIVAR DIGITAL VIDEO RECORDER, BILINX
CONFIGURATION TOOL PROGRAM, OR OTHER BOSCH
SECURITY SYSTEMS CONTROL SYSTEM
ALLEGIANT Video System
VIDEO
ALLEGIANT Bilinx Data Interface
VIDEO + Bilinx DATA
AC
POWER
Bilinx-ENABLED
AUTODOME SERIES
P/T/Z CAMERA
VIDEO
BOSCH
CODE OUT
ALARM
STATUS
BATTERY LOW
POWER
DATA
BOSCH
Status/Power
LTC 8016 ALLEGIANT
BILINX DATA INTERFACE
INTUIKEY® SERIES KEYBOARD
EN | 11
BOSCH
Prod
Mon
Clr
Shot
3
1
2
4
5
6
7
8
9
0

Advertisement

Table of Contents
loading

Table of Contents