Bosch MIC412 Installation And Operation Manual page 32

Dual optical / thermal ptz camera
Hide thumbs Also See for MIC412:
Table of Contents

Advertisement

MIC412TI and MIC412TF Camera | Installation and Operation Manual
Multi Alarm Settings
Learn Alarm Positions
Simply point the MIC400 at the position you would like it to cover when each
numbered alarm is triggered and press
Relay
State,
Activation
and
Re-arm
This function is available only to MIC-400's with the MIC-ALM card fitted or the
MIC400IR Power Supply which has Four (4) Alarm Inputs built in.
The MIC-ALM multi alarm card provides 2 output relays which can be configured to
close or open on given alarm inputs. Relay 1 can be activated from either alarm
inputs 1 to 4 or 1 to 8 and relay 2 with alarm inputs 5 to 8 or 1 to 8.
Bosch Security Systems
Learn Alarm Position
to set this.
The re-arm time is a time in seconds before the MIC returns to its current position
and returns the relay to its prior state. The options for this are 1, 5, 10 or 60
seconds. To send the settings to the MIC select the desired options and then press
Set
Relays.
Lens Recalibration and Frame Integration
This section defines when and how often the Sony Optical Camera block should
perform a recalibration process. The first field Inactivity defines how long in hours it
should be after the last manual control command before the first recalibration
should take place, and the second is a time in days between each successive
recalibration from then on.
To set these enter the appropriate values in the text boxes provided and press
Apply. Alternatively the
Recall Now
Frame Integration Settings
This section defines the
Max Gain
MIC when in Auto Lowlight mode. The drop down lists provides the actual settings
available in dB for gain and FPS for shutter speed. The
command will indicate the current frame rate if required. The values are set by
simply selecting the desired option from the drop down lists.
Issue 8
AAA
button will perform a manual recalibration.
and
Min Shutter Speed
parameters used by the
On Screen Data
EN | 32
auxiliary

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mic412tfMic412ti

Table of Contents