NOTE:
The dual PDU assembly shown in
the AC receptacles and mounting hardware.
Figure 17 Dual PDU assembly
.

1. PDU 1

3. Circuit breakers
5. Mounting hardware
PDU 1
PDU 1 connects to AC power distribution source 1. A PDU 1 failure:
Disables the power distribution circuit.
Removes power from PDMs 1, 2, and 3.
Disables PS 1 in the drive enclosures.
Disables the upper controller power supply.

PDU 2

PDU 2 connects to AC power distribution source 2. A PDU 2 failure:
Disables the power distribution circuit.
Removes power from PDMs 4, 5, and 6.
Disables PS 2 in the drive enclosures.
Disables the lower controller power supply.