Verify Disk Drive Modules - HP D7171A - NetServer - LPr Upgrade Manual

Mass storage upgrade guide
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

Chapter 3
To remove a controller from the boot order, use the right and left arrow
keys to highlight the controller, and then press Enter twice. (This creates a
blank.) The boot order sequence number of the other controller will change
to 0, if necessary.
7. Press Esc to return to the Main Menu. To begin to exit the utility, use the
up and down arrow keys to highlight Quit, and press Enter. When the
message
Rebooting system to change global settings...
Press any key
is displayed, press any key to exit the Symbios Configuration utility and
restart the HP NetServer.

Verify Disk Drive Modules

As the HP NetServer restarts, watch the display monitor to determine whether all
the drives you installed have been detected.
NOTE
Any SCSI devices controlled by the integrated HP NetRAID
controller will NOT be displayed during the boot process.
Any SCSI devices controlled by a SCSI controller without a
boot order number will NOT be displayed during the boot
process.
If no drives in the secondary hot-swap mass storage cage are detected, refer to
Chapter 2 as you do the following:
1. Turn off power to the HP NetServer, and unplug the AC power cord(s).
2. Remove Cover 1.
3. Verify that the power harness is connected correctly to the cage.
4. Verify that the SCSI cable is connected correctly to the cage.
5. Remove the I/O fans to view the SCSI B connector on the I/O baseboard.
Verify that the SCSI cable is connected correctly to the SCSI B connector
on the I/O baseboard.
6. Replace the I/O fans.
7. Replace Cover 1.
8. Reconnect the AC power cord(s), and restart the HP NetServer.
Configure Mass Storage
37

Advertisement

Table of Contents
loading

Table of Contents