Table 6-14 Most Common Microcode Panic Codes (Continued)
Value
Description
0x00501003
Chip and driver incompatibility. Occasionally, the microcode would panic with a
0x00501003 or 0x00503003 code. This was caused by a known problem with the
Symbios 53C810 SCSI processor. The microcode has been modified to handle the
condition. Fixed in microcode revision 8.52.
The panic is a result of the SCSI chip and the SCSI driver not agreeing on either the
slot or ID of the drive. The SP should be replaced.
0x00502001
Parity error (Firmware revision greater than 9.44.00). A SCSI controller chip detected
a parity error during a transfer from data RAM. (Reference the 0x00000012 code.)
0x0050300B
Parity error (Firmware revision greater than 9.44.00). A SCSI controller chip detected
a parity error during a transfer from data RAM. (Reference the 0x00000012 code.)
0x00503003
SCSI processor error. Occasionally the microcode would panic with a 0x00501003 or
0x00503003 code. This was being caused by a known problem with the Symbios
53810 SCSI processor. The microcode has been modified to handle this issue. Fixed
in microcode revision 8.52.
0x00600000
RAID-5 write operation returns incorrect data. This panic could occur in earlier
microcode (for example, revision 8.20) when a disk drive in the LUN returned
incorrect data to the SP during a RAID-5 write operation. The microcode could create
a condition where data written back out to the disk causes more 0x1234560n panics
when the sector is accessed again. The panic condition was observed to reoccur
either immediately on power-up of the failing SP, or at some point after power-up as
the SP conducts a Background Verify on the LUN. This could also happen on a
rebuild.
0x0070000C
Validating a bad sector fails. Occurred when Fast RAID-3 LUNs did a Background
Verify and attempts to validate a bad sector.
0x00800077
SCSI download or PROM flashed. Occurred infrequently during a microcode SCSI
download or during the PROM code flash operation. Microcode 9.x5 fixes all known
occurrences of this panic.
If this panic occurs with the latest release of microcode, obtain the Unsolicited Event
Logs from both SPs and the memory dump, and give them to your Hewlett-Packard
service representative for failure analysis.
0x0080007E
Incorrect state reported by peer. The peer controller in the system declared that this
controller has been removed and must reinitialize before continuing.
0x00800082
Firmware revision (SP microcode) mismatch. The peer controller in the system
advised that this controller is running the wrong revision of firmware and must
reinitialize before continuing.
0x00800084
Controller not configured. This controller should not be present in the current
configuration. This occurs if a system has been set up for single board caching and a
second controller is started.
6-60