Panasonic AJHPM110E - MEMORY CARD PORTABLE RECORDER/PLAYER Operating Instructions Manual page 143

Memory card portable recorder/player
Hide thumbs Also See for AJHPM110E - MEMORY CARD PORTABLE RECORDER/PLAYER:
Table of Contents

Advertisement

Setting the external time code
1
Engage the stop mode.
2
Use the COUNTER button to select [TC].
3
Set the TCG switch to [EXT].
(External time code selection)
Reproducing the time code and user bit
1
Engage the stop mode.
2
Use the COUNTER button to select [TC] or [UB].
3
Press the PLAY
button.
Playback starts and the time code appears on the display.
When the SUPER switch is set to [ON], the time code is
superimposed on the monitor.
2
1
3
2
1
3
4
Make the following settings in setup menu No. 507
(EXT TC SEL).
EXT_L:
The LTC signal input to the TIME CODE IN
connector (BNC) on the rear panel is
recorded as TC.
SVITC:
The VITC signal attached to the serial signal
input to the SDI IN (HD) connector is
recorded as a time code.
SLTC:
The LTC signal attached to the serial signal
input to the SDI IN (HD) connector is
recorded as a time code.
◆ NOTE:
• When SLTC and SVITC is set and an analog composite or SD
SDI input signal is selected, the VITC on the input video signal
is recorded. When 1394 is selected as the input signal, the IEEE
1394 digital input signal time code is recorded.
• Setup menu No. 507 EXT TC SEL does not appear in modes
other than 59.94 Hz and 50 Hz. Locked in SLTC in this mode.
• When setup menu No. 040 VFR REC is set to ON, REC RUN is
selected regardless of the TCG switch setting.
" " : Field 1, field 3
When the time code
"*" : Field 2, field 4
signal cannot be
The colon between the seconds and the frames
read, an asterisk (*)
changes to a period (.) in drop frame mode.
is displayed.
■ Time code when no power is supplied
Also when no power is supplied, the backup function works
enabling the time code generator to provide long-term (about
one year) operation. Accuracy when no power is supplied is
about ±30 s per month.
◆ NOTE:
• Under the conditions listed below when the time code generator
advances regardless of operation mode, the backup function is
enabled
- When the TCG switch on the front panel is set to "PRESET" and
setup menu No. 504 RUN MODE is set to "FREE."
- When the TCG switch on the front panel is set to "EXT" and the
external time code set in setup menu No. 507 EXT TC SEL is
disconnected from connector on the rear panel.
• When settings in setup menu No. 25 SYSTEM FREQ are revised,
advance data is cleared.
Setup: Time Code, User Bit and CTL
143

Advertisement

Table of Contents
loading

Table of Contents