Download Print this page

HP 4400 Release Note page 6

Hp storageworks fabric os 6.2.2e release notes (5697-0809, february 2011 - includes all 6.2.2x versions)
Hide thumbs Also See for 4400:

Advertisement

NOTE:
For information on specific switches and switch firmware supported for interop applications,
see the HP StorageWorks Fabric Interoperability: Merging Fabrics Based on M-series and B-series
Fibre Channel Switches Application Notes.
Security enhancements
Configurable stateless IPv6 auto-configuration is supported.
IPsec with IPv6 support provides greater security for management ports and configurable
security policies for IPv4/IPv6 addresses.
A switch-wide policy requiring HBA authentication requires that the FC-SP bit be set during
Fabric login (FLOGI). If the bit is not set, the FLOGI is rejected and the port is disabled.
A new warning for RADIUS login allows users to specify how many days in advance they
should be notified of password expiration.
An LDAP enhancement adds the ability to provide an alternate UPN to domain authentication.
Port beaconing support
The portBeacon CLI command was added in Fabric OS 6.2.1. It allows individual ports to be
identified by enabling a special LED function. The portBeacon command has the following
characteristics:
Function: Sets port beaconing mode on or off.
Syntax: portbeacon - mode [slot]/port
Description: Enables or disables port beaconing mode on a specified port. This command
works with 4-Gb (or larger) FC ports, with the exception of the HP StorageWorks SAN Director
6 Port 10-Gb FC ISL Blade (FC10-6).
When beaconing mode is enabled on a port, the port LED flashes amber and green for 2.5
seconds each, in an alternating pattern, and continues until you turn it off. Beaconing mode
is useful if you want to locate a specific port.
Beaconing mode takes over the port LEDs. The normal flashing LED pattern associated with
an active, fault, or disabled port is suppressed, and only the beaconing pattern is displayed.
Other commands are still executable and functional. However, if diagnostic frame-based tests,
such as the portLoopbackTest, are executed, the diagnostic LED pattern is interleaved with the
port beaconing pattern.
Operands:
Examples:
To turn beaconing mode on: switch:admin> portbeacon
To turn beaconing mode off: switch:admin> portbeacon
Diagnostics restrictions
The porttest and spinfab commands are not supported on the following ports in Fabric OS
6.2.1 or later:
Ports connected to shared-area ports (ports 16–47 on 48-port blades)
Ports connected to ports with area swapped
ICLs
Slave ports in trunk groups
Long-distance ports
Ports connected to a logical switch and base switch (Fabric OS 6.2.x only), if VF is enabled
6
enable turns beaconing mode on;
disable turns beaconing mode off.
enable 1/0
disable 2/1

Advertisement

loading

This manual is also suitable for:

Fabric os 6.2.2e