Table 12 Fabric OS 6.2.2a closed defects (continued)
Closed defect summary
While running Fabric OS 6.2.2, the switch can panic after executing a
fcplunquery or iscsicfg CLI command for the target entity on HP
StorageWorks iSCSI Director Blade. An FCPD termination occurs if a PRLI
or Report LUN query times out during fcplunquery/iscsicfg command
and the LOGO response is missing a message queue required for
processing, resulting in a switch panic.
Fabric class areas Zoning Changes in fwconfigure does not function
correctly. Zone changes are not recorded in the FW module, resulting in
threshold alarms not being raised as appropriate.
After using the ipaddrset -cp command to set a CP blade or director
switch host name, the standby CP incorrectly displays the CP host name
instead of the chassis host name. For the change to take effect, after
upgrading the firmware, the user must logout, and then log back in.
During reboot, HP StorageWorks D2D Backup System device sends the
explicit logout; however, the switch does not clean up the route properly,
resulting in the hosts being unable to detect the tape devices.
Username/password authentication can fail when using Microsoft Active
Directory (LDAP) from Server 2008 for authentication. Users can experience
problems after upgrade from a Microsoft Windows host using older versions
of the LDAP protocol for authentications.
After using the snmpconfig -set snmpv command to set SNMPv3, the
switch configdownload command failed with the following message:
snmp.snmpv3Usm.0.usmPrivProtocol:6 Invalid Value.
If you set fwsettocustom, the HP StorageWorks DC SAN Backbone
Director does not output FW- 1 003/FW- 1 004 after an hafailover or reboot,
and you will not be notified about temperature over threshold events.
The systemverification and portloopbacktest diagnostic tests report marginal
blade failures on an HP StorageWorks DC SAN Director, but after the tests
are complete, Fabric Watch reports switch is healthy.
Fabric OS 6.2.2b fixes
Table 13 (page 43)
Table 13 Fabric OS 6.2.2b closed defects
Closed defect summary
After upgrading EFCM to 9.7.4 and HP StorageWorks 4/256 SAN director
to 6.2.0x, customer is unable to discover switches due to performance of
SNMP get for connUnitLinkTable being reduced in 6.2.x.
Excessive internal messages cause a RASLOG flood condition and a
weblinkerfcg message appears on FCIP switches in the fabric (HP
StorageWorks 1606 Extension SAN Switch and Multiprotocol Extension
Blade). This can lead to other important RASLOG messages being lost. This
issue has no functional impact and occurs on platforms not running ipsd
(IP Security Daemon).
No cascaded FICON CUP connectivity on 4/256 Director with 8Gb blade
when E_Port and F_Port are on different ASICs on the blade.
Under heavy CPU load, SFP laser fault condition may cause links to reset.
lists defects closed in the Fabric OS 6.2.2b firmware release.
Solution
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Solution
Fixed in Fabric OS 6.2.2b
Fixed in Fabric OS 6.2.2b
Fixed in Fabric OS 6.2.2b
Fixed in Fabric OS 6.2.2b (New
parameter added to Fabric OS 6.2.2b to
allow adjustment of SFP polling interval
to avoid laser faults.)
Fabric OS 6.2.2b fixes