Log Messages
System-related Log Messages
GS001 Ethernet interface initialization failed (crit)
Message
Explanation
Response
GS002 Ethernet route registration failure (err)
Message
Explanation
Response
GS003 Ethernet default route registration failed (err)
Message
Explanation
Response
GS004 System startup (info)
Message
Explanation
GS005 System settings changed (info)
Message
Explanation
GS006 IP address conflict detection at startup (err)
Message
%1
%2
Explanation
Response
152
eci: netif can't up
Network interface initialization failed.
If rebooting does not resolve the problem, contact an authorized Canon service representative.
eci: net route can't add
An attempt to register a route for a local Ethernet segment failed.
Correct the Ethernet settings and reboot.
eci: default route can't add
Registration of the default Ethernet route failed.
Correct the Ethernet settings and reboot.
System started
The VB software started up.
System settings updated
The VB software settings were modified without a reboot.
Detected a conflict for IP address %1 with %2
IP address
Ethernet address
An IP address conflict was detected during startup. If there is a device running on the network that
has the same IP address as the VB101, this error occurs when the VB101 starts up.
Change the VB101 IP address or change the IP address of the conflicting network
device. If you change the VB101 IP address, the VB101 must be rebooted.
When there is an IP address conflict, it may not be possible to modify the settings
via Ethernet. In this event, an initial setup tool must be used to change the settings.