Automatic Logon - Bosch DB24C4200R2 Release Notes

Release notes
Hide thumbs Also See for DB24C4200R2:

Advertisement

Security Systems
From
Our Reference
ST-VS/PRM4
Andreas Baumann
DiBos 8.5 release notes
1.5
DiBos SW for ATM/POS-bridge (DB-SE-016)
This new part number is a software extension to allow customers to connect to Bosch
ATM/POS Bridge. The data coming from the ATM/POS Bridge is treated as metadata
and can be recorded with the camera image.
1.6
DiBos SW for IP-server (DB-SE-017)
This new part number is a software extension that allows customers to connect to an
IP-server sending data (e.g. POS data). This data is treated as metadata and can be
recorded with the camera image. The port of the IP server and specific strings to start
and to end the recording can be individually configured.
1.7
New Sales Demo License option
There is a new Sales Demo License option available. This is intended to be used by
our sales force. The license is featuring the IP recorder software for 4 IP cameras.
Unlike the normal Demo software it does not expire. The limitation is an automatic
shutdown of the software 4 hours after start.
The license option CTN is DB-SDE-042, it can not be purchased but is provided to
each Product Marketing Manager by the BU.
1.8
DiBos stores entered values
DiBos 8.5 stores the export path of the last video export.
DiBos 8.5 stores the last search entries for meta data.
1.9
DiBos recording information
It is now possible to display the database information of a DiBos Recorder from a
DiBos remote client.
1.10 The configuration file includes also computer specific settings
The DiBos configuration file (vidsys.prm) includes the following computer specific
settings: Regional settings, TCP/IP settings (e.g. IP Address), Computer name.
When loading the file DiBos asks for confirmation if the computer specific settings
should overwrite the current settings.
1.11 Different user permissions for alarm cameras
It is now possible that an alarm camera has a different permission than in idle mode.
This way a user can see a camera image only when this camera is part of an alarm.
In the "normal" live mode this camera would not be accessible.

1.12 Automatic logon

It is now possible to logon to the DiBos application automatically with a simple
command line:
"C:\Program Files\DiBos\Video.exe" /user=<username> /pw=<password>