Replacing A Fan Module; Before You Begin; Verifying Component Failure; Removing The Component - HP 201723-B21 - StorageWorks Modular SAN Array 1000 Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive:
Table of Contents

Advertisement

Replacing a fan module

The variable-speed fan module is hot-pluggable, so it is not necessary to power down the system to
replace it.

Before you begin

CAUTION:
Before removing a component or blanking panel from an operational device, make sure that you
have the replacement part available. Removing a component or blank impacts the airflow and
cooling ability of the device. To avoid possible overheating, insert the new or replacement component
within one or two minutes. If the internal temperature exceeds acceptable limits, the device may
overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
CAUTION:
Replacement power supply assemblies do not include a variable speed fan. You must remove the
operational fan from the defective power supply and install the fan on the new power supply.
The fan blades rotate at a high speed and do not stop immediately when power is removed from
the MSA. Allow time for the blades to stop rotating. Avoid touching the rotating blades when
removing the fan.
The fan shell must be handled carefully to avoid breaking it. Do not press on the center section of the
fan shell (circular panel covering the blades). To avoid damaging the fan blades, grasp only the
outer portion of the fan shell. Do not rest the power supply on the fan. Doing so might break the fan.

Verifying component failure

Check the array controller LCD display panel for error messages.
Verify that the electrical source is delivering power down the AC power cord.
Verify that the blower module fault LED is flashing amber.
Verify that the blower module Power on/off LED is Off.

Removing the component

1.
Review all warnings, cautions, and preparation procedures as detailed in
2.
Push in the two fan tabs (1) while pulling the fan element away from the power supply (2).
88
Customer replaceable components
Warnings and
precautions.

Advertisement

Table of Contents
loading

This manual is also suitable for:

353803-b22 - storageworks modular smart array 1000 san starterStorageworks 1000 - modular smart arrayStorageworks 1000

Table of Contents