Chassis specifications
Height
Width
Depth
Weight (no hard drives installed, single power supply)
International input voltage requirements
Rated input voltage
Rated input frequency
Rated input current
Input power (max)
U.S. input voltage requirements
Rated input voltage
Rated input frequency
Rated input current
Input power (max)
Power supply specifications
Rated steady-state power
Maximum peak power
Btus
Temperature range
Operating
Shipping
Relative humidity (noncondensing)
Operating
Non-operating
Maximum wet-bulb temperature
Long term storage
Short term storage
Idle
Fixed drive (random writes)
* Input power and heat dissipation specifications are maximum values and apply to worst-case conditions
at full rated power supply load. The power/heat dissipation for your installation varies depending on the
equipment configuration.
16
Specifications
Item
Description
17.5 cm (6.9 in)
52.1 cm (20.5 in)
48.3 cm (19.0 in)
22.7 kg (50 lb)
100 to 240 VAC
50 Hz to 60 Hz
7.35 A Max
641 W*
100 VAC to 240 VAC
50 Hz to 60 Hz
7.35 A Max
641 W*
377 watts
681 watts
2187 Btu/hr*
10° to 35° C (derated 1°C per 1000 feet of elevation
to 10000 ft.); (50° to 95° F)
-30° to 50° C (-22° to 122° F)
10% to 90%
up to 95%
29°C (84.2°F)
30°C (86°F)
<6.9 and 53
<7.3 and 54