Above-Reservoir Installation - Bosch Rexroth A10VSNO Instruction Manual

Axial piston variable pumps
Hide thumbs Also See for Rexroth A10VSNO:
Table of Contents

Advertisement

30/60
Installation
Bosch Rexroth AG, A10VO, A10VSO, A10VSNO Series 32, RE 92714-01-B/04.2018
7.3.3

Above-reservoir installation

Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.
To prevent the axial piston unit from draining, a height difference h
25 mm at port T is required in installation position 8.
Observe the maximum permissible suction height h
permissible suction height h
Because complete air bleeding and filling is not possible in installation position 8,
the axial piston unit should be air bled and filled in a horizontal position prior to
installation.
7
T
F
h
L
SB
L
S
h
1
S max
h
t min
h
min
Fig. 9: Above-reservoir installation A10VO with installation positions 7–9
Highest drain port
L, L
1
F
Filling/air bleeding
S
Suction port
h
Minimum required immersion depth
t min
(200 mm)
Port F is part of the external piping and must be provided on the customer side
to make filling and air bleeding easier.
Table 10: Above-reservoir installation
Installation position
7 (drive shaft horizontal)
8 (drive shaft up)
9 (drive shaft horizontal)
S max
is derived from the total pressure loss.
S
8
F
T
ES min
L
1
S
SB
h
S max
h
t min
h
min
h
Minimum required distance to
min
reservoir bottom (100 mm)
h
Minimum required height needed
ES min
to protect the axial piston unit from
draining (25 mm)
h
Permissible suction height (800 mm)
S max
SB
Baffle plate
Air bleed
F
F
F
of at least
ES min
= 800 mm. The
9
L
1
S
F
T
h
S max
SB
h
t min
h
min
Filling
L (F)
L
(F)
1
L
(F)
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a10voRexroth a10vvsoRexroth 32 series

Table of Contents