Control Board Diagnostics - Bosch 830 ES Installation And Operating Instructions Manual

Hide thumbs Also See for 830 ES:
Table of Contents

Advertisement

7.6

Control board diagnostics

1. Press ON/OFF button
2. Press and hold simultaneously buttons
for 3 seconds, until display reads P2.
3. Press
to enter P2 adjustment. The current setting will
P
appear on the display. If not, repeat process.
4. Press and release the
the display reads 'P4'. You are now in the diagnostic mode
of the control board.
5. When the display reads 'P4', press and release the
button once again and the display should read 'E'.
6. Use the
+
and
button on the control board to cycle
through different diagnostic modes available.
7. Once in the selected diagnostic mode of your choice, press
and release the
button to display the diagnostic
P
information.
EXAMPLE: to read the flow rate in gallons per minute while the
unit is flowing water, cycle to the '3d' mode and press the
button. A reading of 25 on the display would indicate the heater
is reading a flow rate of 2.5 gallons/minute.
8. Once the information is obtained, press the
again to return to the diagnostic mode menu and scroll to
addition diagnostic information.
9. Press ON/OFF button to turn OFF the appliance and back
ON again to return heater to normal function.
Diagnostic menu
E
Entry/Exit into sub-modes
0d
Heat exchanger water temperature
1d
Inlet water temperature (°F)
2d
Outlet water temperature (°F)
3d
Water flow (gallons/min)
4d
Bypass control monitor (°F) [0d - 2d]
5d
Fan speed (Hz)
6d
Burner power (%)
7d
Maximum power (kW)
8d
Back flow temperature (°C)
9d
Exhaust temperature (°C)
1F
Most recent error/failure
2F
2nd most recent error
3F
3rd most recent error
4F
4th most recent error
5F
5th most recent error
6F
6th most recent error
7F
7th most recent error
8F
8th most recent error
830 ES – 6 720 644 936 (2021/08)
into ON.
+
,
and
button on the control panel until
P
button
P
Diagnostic menu
P
9F
9th most recent error
10F
10th most recent error
1P*
Appliance type - Cd (Condensing)
Appliance type - nC (Non condensing)
2P*
Appliance power - 175 / 199 (kBTU/hr)
3P*
Temperature range - H (100-140°F)
Temperature range - C (100-184°F)
+
H0
Numbers of hours - mode 0
H1
Numbers of hours - mode 1
H2
Numbers of hours - mode 2
Table 38 * Settings define from factory
7.6.1 Working hours
To see how many hours the appliance has worked, please enter
the "Diagnostic menu" (chapter 7.6);
P
▶ Select the sub-mode "H0".
Write the number that shows in the display.
▶ Select the sub-mode "H1".
Write the number that shows in the display.
▶ Select the sub-mode "H2".
Write the number that shows in the display.
After checking the sub-modes H0, H1 and H2, introduce the
values in the table below;
Working hours
Number in H0
Number in H1
Number in H2
(H0 + H1 + H2) = Total of hours
Table 39
Example:
Calculation of number of working hours,
Working hours
Number in H0
Number in H1
Number in H2
(H0 + H1 + H2) = Total of hours
Table 40
Maintenance and service
______
______ (X 100) =
______ (X 10 000) =
60
5 (X 100) =
0 (X 10 000) =
_______ +
_______ +
_______
__________
60 +
500 +
0
560
57

Advertisement

Table of Contents
loading

Table of Contents