Fig. 9
Concentric kit vent assembly
Fig. 10
Concentric kit installation
[1] 12 inches
[2] 3 inches stainless steel pipe
4.3.2 Vent specifications
An improperly sized venting system may lead to undesired
effects such as the formation of condensate, gas leakage or
spillage.
Install appliance as close to point of vent termination as
possible. The exhaust piping must vent directly to the outside of
the structure.
830 ES – 6 720 644 936 (2021/08)
Horizontal sections of vent must pitch upward towards
termination ¼" for every foot of horizontal length, to prevent the
pooling of condensate, and be supported at 4 foot intervals
with overhead hangers.
Exception: horizontal run between last elbow and termination
must pitch down to termination 1/4" per foot. Note: For
horizontal terminations, venting must terminate once it
penetrates to the outside of the structure. There must be no
sections of vent pipe exposed to the outdoors other than the
termination. Note: Listed thimbles or collars are necessary
where venting passes through wall and ceiling partitions. If the
vent system passes through combustible areas where the vent
clearance requirements cannot be maintained, it is permissible
to chase straight sections of sealed 3 inch single wall vent
through 4 inch (or greater) Type-B vent. The distance to
combustibles using this chase technique is 1 inch. Note: Type-
B vent must never be used as the actual exhaust vent system for
the appliance, as it is not gas tight and illegal for use with this
appliance. This will create a serious health hazard and void the
warranty.
3" VENTING
Z flex
3"
2SVEEWCF0390 FSELB9003 9314
90° elbow
3" Tee Terminal 2SVSTTF03
3" Horizontal
2SVSTB03
Terminal
with damper
2SVSHTD03
3" Vertical
2SVSRCF03
Terminal
Table 6
3" Terminator Part Numbers
4" VENTING
Z flex
4"
2SVEEWCF0490 FSELB9004 9414
90° elbow
4" Tee Terminal 2SVSTTF04
4" Horizontal
2SVSTB04
Terminal
with damper
2SVSHTD04
4" vertical
2SVSRCF04
terminal
Table 7
4" Terminator Part Numbers
For specific questions concerning vent material,
specifications, usage or installation, please contact the vent
manufacturer directly.
Installation instructions
Protech
Heat Fab
FSTT3
9390TEE
FSTB3
N/A
N/A
N/A
FSRC3
5300CI
Protech
Heat Fab
FSTT4
9490TEE
FSTB4
N/A
FSRC4
5400CI
N/A
N/A
17