Haier HHS-1X5K User Manual page 32

Battery energy storage system
Table of Contents

Advertisement

Battery module charging low
temperature protection
Automatic shutdown at low battery
voltage
Battery module failure
Short discharge time
Unable to charge and discharge
After the system is powered on, the
display cannot be lit or the
displayed content is abnormal
The display cannot wake up and
light up during system operation
The number of battery icons
displayed on the display screen is
inconsistent with the actual number
The system status light on the
1. The product installation
environment is too low
2. The heating film of the battery
module works abnormally
The battery is over-discharged and
not recharged in time
Internal failure of battery module
battery SOC is low
low ambient temperature
Product overload
Batteries age and capacity decreases
Internal failure
Battery report charging or
discharging protection failure
After the battery is discharged to
the SOC protection value, it needs
to be charged for a period of time
before it is allowed to discharge.
battery over temperature
1.Display failure
2.Control module fault
1. If the POWER button light is off,
the POWER button is faulty or the
button wiring is loose
2. If the display still does not light
up after restarting, the display is
faulty
Communication disconnection
Battery module failure
29
3. If the ventilation and ambient
temperature are normal,please
contact the supplier for more
information
1. Check whether the ambient
temperature exceeds the minimum
allowable charging temperature
range. If the ambient temperature is
too low, please improve the
environment
2.Please contact the supplier for
more information
1. The inverter is set with charging
mode, which can charge the battery
through the grid or PV
2. Restart the battery and charge it
through the inverter
3.Please contact the supplier for
more information
Log in to the PowerLite APP to
view the fault information and
contact the supplier
Keep the product charged
continuously and keep the energy
storage battery system fully charged
Guarantee the product to work
within the recommended suitable
temperature range
Check load status and remove
non-essential loads
To replace the battery, please
contact the supplier for the battery
and its components
Log in to the PowerLite APP to
view the fault information and
contact the supplier
Log in to the PowerLite APP to
view the fault information and
contact the supplier
The battery is charged to the SOC
value set by the restart
Stand at room temperature for more
than 3 hours
1.Please try restarting the battery
2.Log in to the PowerLite APP to
view the fault information and
contact the supplier
3.Please contact the supplier to
repair or replace the control module
1. Log in to the PowerLite APP to
view the fault information
2. Please try restarting the battery
3.Please contact the supplier to
repair or replace the control module
1.Check whether the battery stack is
installed reliably, and confirm the
abnormal battery through the
battery status indicator on the
display
2. Please try restarting the battery
3.Please contact the supplier to
repair or replace the battery module
Log in to the PowerLite APP to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hhs-1x10kHhs-1x15kHhs-1x20k

Table of Contents