Table 4- 12
X1: Line connection for Active Line Modules 16 kW
For ring cable lugs without insulation
1)
Table 4- 13
X1: Line supply connection for Active Line Modules 36 kW to 120 kW
For ring cable lugs without insulation
1)
178
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Terminal
U1
V1
W1
PE connection
Terminal
U1
V1
W1
PE connection
Technical data
Max. connectable cross-section: 10 mm
Type: Screw terminal 6 (Page 755)
Tightening torque: 1.5 ... 1.8 Nm
Threaded hole M5 / 3 Nm
1)
Technical data
Supply voltage:
380 ... 480 V 3 AC, 50/60 Hz
36 kW: Threaded bolts M6 / 6 Nm
55 kW, 80 kW and 120 kW: Threaded bolts M8 / 13 Nm
36 kW and 55 kW: Threaded hole M6 / 6 Nm
80 kW and 120 kW: Threaded hole M8 / 13 Nm