Servicing the Air Cleaner (continued)
Do not apply pressure to the flexible center of the filter.
4. Remove the dust-ejector valve from the air-cleaner cover, clean the cavity, and install
the ejector valve to the cover.
5. Assemble the cover onto the air-cleaner housing, aligning the dust-ejector valve in a
downward position—between approximately 5 o'clock to 7 o'clock when viewed from the
end.
6. If a red band displays in the service indicator,
press the reset button at the end of the
indicator.
7. Close and latch the hood.
Fuel System Maintenance
Inspecting the Fuel Lines and Connections
1. Prepare the machine for maintenance.
2. Open the hood.
3. Inspect the fuel lines for wear, deterioration, damage, or loose fittings.
Note:
4. Close and latch the hood.
Maintenance: Fuel System Maintenance
Repair or replace any worn or damaged fuel lines; tighten any loose fittings.
IMPORTANT
G424758
Page 6–18
3466-706 A