Air extraction
important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature
variations exist, it may
need to be insulated to reduce
condensation.
-
If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
_iii
iiiiiiiiiiiiiiiiiisiiiiiiiiiiiiiiiiiiiiiiiiiii_
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting
an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Condensate
trap
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate
which may
OCCUK
olso
(5 7/8,,)
r_r _
o125 mrn
[] When installing a condensate
trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outleL
34