Flip Detect Problem - Motorola MotoRAZR maxx V6 Manual

Hide thumbs Also See for MotoRAZR maxx V6:
Table of Contents

Advertisement

Motorola GmbH, Mobile Devices, CSS Center
Title:
Troubleshooting-Guide MotoRAZR maxx V6

Flip detect problem

Units with a flip detect problem will show following symptoms:
-
no power on via battery
-
no main display via EMU connector supply
-
CLI display is not switching on open/close flip
-
No keypad function
Check
FLIP_DETECT_F
VIPU_1_8V
at R2316-1. If 1.8Vdc are present check
joints/solder shorts/defective part – if ok it is most likely a problem with the ARGON
forward to an authorized level 4 service center.
Repair Support Information
at
R2316-2
– should be 1.8Vdc (High signal), if it is low check
Figure 22
© Copyright 2003-2007 Motorola Inc. All Rights reserved.
Motorola internal use
Doc. No:
Version:
Date:
Page:
J2300/FL2306
for dry solder
TSG_3G_V6
1.0
23.07.2007
21 / 40
U1000